BS EN 50306-4:2020 pdf free.Railway applications – Railway rolling stock cables having special fire performance – Thin wall Part 4: Multicore and multipair screened or not screened sheathed cables.
This document specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated voltage ticlU: 300/500 V. of the following types:
— unscreened. sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 48):
— screened, sheathed for either exposed or protected wiring (0.5 mm2 to 2.5 mm2. number of cores from 2 to 8);
— unscreened. sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of screened pairs of cores from 2 to 7).
— screened, sheathed for either exposed or protected wiring (0,5 mm2 to 1.5 mm2, number of unscreened pairs of cores from 2 to 7).
All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered.
These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 110 °C120 000 h temperature index. If the customer were to require lifetime predictions this would be demonstrated based on the temperature index of the product as supptied by the manufacturer.
The maximum temperature for short circuit conditions is 160 C based on duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545-1 and EN 45545-2.
EN 50306-4:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements. EN 50306-2:2020, Single core cables, and EN 50306-3:2020, Single core and multicore cables.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISOOnline browsing platform: available at httøs:Ilwww.iso.orglobp
— IEC Electropedia: available at httixllwww.electropedia ,orql
4 Multicore cables – sheathed
4.1 General
The completed cables shall conform to the applicable general requirements given in EN 50306-1:2020 and to the specific requirements of Clause 4 and Clause 5.
Conformity with the requirements shall be checked by inspection and by the tests given in Table 2.